{"id":1651,"date":"2021-01-25T09:00:00","date_gmt":"2021-01-25T12:00:00","guid":{"rendered":"https:\/\/revistaabcd.org.br\/?p=1651"},"modified":"2022-04-14T05:25:20","modified_gmt":"2022-04-14T08:25:20","slug":"development-and-validation-of-a-new-laparoscopic-endotrainer-for-neonatal-surgery-and-reduced-spaces","status":"publish","type":"post","link":"https:\/\/revistaabcd.org.br\/pt-br\/development-and-validation-of-a-new-laparoscopic-endotrainer-for-neonatal-surgery-and-reduced-spaces\/","title":{"rendered":"DEVELOPMENT AND VALIDATION OF A NEW LAPAROSCOPIC ENDOTRAINER FOR NEONATAL SURGERY AND REDUCED SPACES\u00a0"},"content":{"rendered":"

Background:<\/h2>\n\n\n\n

Pediatric procedures have the difficulty of being performed in reduced spaces. Training in reduced spaces has proven to be different in complexity compared to adult laparoscopic endotrainers.<\/p>\n\n\n\n

Aim:<\/h2>\n\n\n\n

To develop and validate a new neonatal\/reduced-space endotrainer.<\/p>\n\n\n\n

Methods:<\/h2>\n\n\n\n

The simulator was tested and assessed by users with different skill levels and experience in laparoscopic pediatric surgery through an 8-item questionnaire. Construct validity was determined by evaluating the performance of each subject on nine exercises.<\/p>\n\n\n\n

Results:<\/h2>\n\n\n\n

A 10.5 x 10 x 18 cm acrylic simulator was created, with an internal working surface of 9 x 9 cm. An HD camera was incorporated, with a 0-180\u00b0 range of movement. All exercises of a Basic Laparoscopic Training Program were adapted on a scale of 1:0.5 to fit in. From 49 participants, 42 (85.71%) answered the survey; 80.5% considered that the simulator reproduces similar conditions to procedures performed in children under one year of age; 61.1% thought that the simulator represents a difficulty identical to procedures performed in newborns; 73.7% considered that the neonatal simulator is more complicated than the adult simulator. Experts showed significantly better performance in all proposed exercises.<\/p>\n\n\n\n

Conclusion:<\/h2>\n\n\n\n

The simulator has a high-quality image and design that allows training with basic tasks. The endotrainer permitted to discriminate between these different skill levels and was well evaluated by users with diverse surgical experience.<\/p>","protected":false},"excerpt":{"rendered":"

Background: Pediatric procedures have the difficulty of being performed in reduced spaces. Training in reduced spaces has proven to be different in complexity compared to adult laparoscopic endotrainers. Aim: To develop and validate a new neonatal\/reduced-space endotrainer. Methods: The simulator was tested and assessed by users with different skill levels and experience in laparoscopic pediatric […]<\/p>","protected":false},"author":6,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_lmt_disableupdate":"no","_lmt_disable":"","footnotes":""},"categories":[14],"tags":[432,428,429,430,431],"acf":[],"modified_by":"Doris","_links":{"self":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts\/1651"}],"collection":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/comments?post=1651"}],"version-history":[{"count":2,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts\/1651\/revisions"}],"predecessor-version":[{"id":1661,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts\/1651\/revisions\/1661"}],"wp:attachment":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/media?parent=1651"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/categories?post=1651"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/tags?post=1651"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}