{"id":2713,"date":"2018-06-28T10:49:00","date_gmt":"2018-06-28T13:49:00","guid":{"rendered":"https:\/\/revistaabcd.org.br\/?p=2713"},"modified":"2022-05-31T10:56:22","modified_gmt":"2022-05-31T13:56:22","slug":"new-bowel-preparation-technique-for-colonoscopy-clinical-trial-comparing-aquanet-and-mannitol","status":"publish","type":"post","link":"https:\/\/revistaabcd.org.br\/pt-br\/new-bowel-preparation-technique-for-colonoscopy-clinical-trial-comparing-aquanet-and-mannitol\/","title":{"rendered":"NEW BOWEL PREPARATION TECHNIQUE FOR COLONOSCOPY: CLINICAL TRIAL COMPARING AQUANET AND MANNITOL"},"content":{"rendered":"

Background:<\/h2>\n\n\n\n

Fifty-five percent of Americans aged 50-65 are submitted to colonoscopy. For over 65-year, this number increases to 64%. In Brazil, it is forecast that the population submitted to colonoscopy will grow, even though inadequate preparation is still a major problem.<\/p>\n\n\n\n

Aim:<\/h2>\n\n\n\n

To analyze the quality of a new intestinal preparation technique, Aquanet EC-2000\u00ae<\/sup>, compared to oral Mannitol solution.<\/p>\n\n\n\n

Methods:<\/h2>\n\n\n\n

This prospective longitudinal study enrolled 200 patients with indication for colonoscopy. The sample was randomly allocated to two groups of 100; one group received Aquanet EC-2000\u00ae<\/sup> to prepare for colonoscopy and the other Mannitol solution. The Boston scale was used to analyze the results.<\/p>\n\n\n\n

Results:<\/h2>\n\n\n\n

As expected both preparations produced similar results with the bowel cleansing of the different regions of the colon being classified as Boston scale 3 (excellent) in most patients (p>0.05).<\/p>\n\n\n\n

Conclusion:<\/h2>\n\n\n\n

The results of bowel preparation using Aquanet EC-2000\u00ae<\/sup> were similar to using Mannitol solution.<\/p>","protected":false},"excerpt":{"rendered":"

Background: Fifty-five percent of Americans aged 50-65 are submitted to colonoscopy. For over 65-year, this number increases to 64%. In Brazil, it is forecast that the population submitted to colonoscopy will grow, even though inadequate preparation is still a major problem. Aim: To analyze the quality of a new intestinal preparation technique, Aquanet EC-2000\u00ae, compared […]<\/p>","protected":false},"author":6,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_lmt_disableupdate":"","_lmt_disable":"","footnotes":""},"categories":[9],"tags":[377,735,294,274,275],"class_list":["post-2713","post","type-post","status-publish","format-standard","hentry","category-original-article","tag-clinical-protocols","tag-clinical-trial","tag-colonoscopy","tag-comparative-study","tag-propensity-score"],"acf":[],"modified_by":"Doris","_links":{"self":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts\/2713"}],"collection":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/comments?post=2713"}],"version-history":[{"count":0,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/posts\/2713\/revisions"}],"wp:attachment":[{"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/media?parent=2713"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/categories?post=2713"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/revistaabcd.org.br\/pt-br\/wp-json\/wp\/v2\/tags?post=2713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}