Since publication of our paper “Ten Golden Rules for a Safe MIS Inguinal Hernia Repair” we have received many questions. As the authors, we feel it is important to address these topics as a follow-up to our paper.
To discuss in more details the main points of controversy, review the rules and update de recommendations.
The questions and discussions came mainly over five rules, numbered 3, 5, 6, 7, 10. We analyzed all the comments about recommendations and update some technical principles.
Rule 3 - Removing normal fat plugs from the obturator canal is unnecessary and therefore is not recommended; Rule 5 - transection of the uterine round ligament (1 cm proximal to the deep ring) facilitates adequate dissection. When performed in this way it does not appear to be associated with complications; Rule 6 - transection of huge sacs are safer than over-dissection of the cord structures. Whether dissecting completely the sac or abandon the distal part it results in less postoperative seromas is an ongoing debate; Rule 7 - any retroperitoneal structure traversing the internal ring is or play a role like a hernia. Failing to identify and remove the lipoma will ultimately result in the patient experiencing a recurrence; Rule 10 - in TAPP peritoneum should preferably be closed with suture than tackes.
10 Golden Rules emphasize the most important surgical tips and technical steps that allow the safe performance of MIS repairs of inguinal hernias, regardless the technique.